Periodically pull up a tile and check the back to ensure proper adhesive coverage. MAPEI Ultralite Mortar Pro ’s unique Ultralite Technology™ provides twice the coverage of a standard thin-set mortar per pound/kg and may contribute to LEED points with more than 20% recycled content. Clean with water before the material dries. (13.6 kg) bag covers the same area as a 50 lb. Apply the primer coat to the floor at a rate of 300 ft2/gal (7.5 M2/L). Installation must comply with the requirements of all applicable local, state and federal code jurisdictions. Mixing thin set can really be a hassle if you don't have the right tools and the right knowledge to get the job done. Terms | Use extreme caution; adhesives may contain asbestos fibers. Mortar thickness should be less than 3/4" when beat in. Submerged installations must cure for 14 days before filling with water. Mixing Ratios Mix 5.75 - 6 qts (5.4 - 5.7 L) clean water to 30 lb (13.6 kg) bag of mortar. Do not sand flooring materials containing asbestos. For questions about proper subfloor installation requirements, call Custom® Technical Services. When setting glass tile larger than 6" x 6" (15 x 15 cm), contact Custom's® Technical Services for recommendations. Using the flat side of the trowel, apply a skim coat of mortar to the surface. Start with that, and if the mixture isn't like a super-thick milkshake (Wendy's Frosty), add 1/2 part water or mortar mix at a time until it sticks to the side of the … VersaBond-LFT exceeds ANSI A118.4 and A118.11. Surfaces to be tiled must be structurally sound and subject to deflection not to exceed current industry standards. Adjustments allowed, yet it will set quickly, allowing the grouting process to begin in under 3 hours with light traffic in 4 hours. With a non-slumping formula to eliminate lippage, Versabond-LFT can be applied to 3/4" (19 mm) thick on horizontal applications. Formulated with CustomLite® Technology, ProLite® is 40% lighter than traditional mortars. Plywood floors, including those under resilient flooring, must be structurally sound and must meet all ANSI A108.01 Part 3.4 requirements. Preparing your surface is the most critical task of any tile or stone installation. Refer to the individual product data sheet or packaging directions for application instructions. Precision demands the best. Formulated with CustomLite® Technology, ProLite® is 40% lighter than traditional mortars, providing excellent handling characteristics. Refer to TCNA F144-13 tile installations and TCNA F-250-13 for stone. If the material has skinned over (not sticky to the touch), recomb with the notch trowel; if too dry, remove and replace the dry material with fresh material. ProLite® offers high bond strength in a lightweight formula with excellent handling characteristics for a wide variety of floor and wall tile installations. This mortar mix ratio is very similar to type O mortar, so be sure to carefully measure your ingredients when making either type. Existing Ceramic Tile, Resilient Flooring or Plastic Laminates: Resilient flooring or plastic laminates must be well bonded, as well as clean and free of all contaminates. When it comes to mixing a 50-pound bag for tile, add 5 cups of cool water. (22.68 kg) bag of traditional mortar. Mix by hand or use a low 150-200 RPM speed 1/2" (13 mm) drill to achieve a smooth, paste-like consistency. For interior and exterior installations. When backbuttering, consider the tile underside pattern and depth to estimate thickness and usage to add to your estimate. Remove all grease, oil, dirt, curing compounds, sealers, adhesives or any other contaminant that would prevent a good bond. Using the flat side of the trowel, apply a skim coat of mortar to the surface. Our grouts are easy to work with yet deliver hard, dense joints. To determine desirable results, do a test bond area before starting. They must be brought through the tile work and filled with an appropriate elastomeric sealant, such as Custom's® 100% Silicone. Test by sprinkling water on various areas of the substrate. For more information, find details and limitations to this warranty at custombuildingproducts.com. Maximum allowable deflection: L/360 tile L/720 stone. Preparing your surface is the most critical task of any tile or stone installation. Use of this product can contribute towards LEED® v3 certification: USE CHEMICAL-RESISTANT GLOVES, such as nitrile, when handling product. Allow 7-10 days before heavy or vehicular traffic. Adhesive residue must be wet-scraped to the finished surface of the concrete, leaving only the transparent staining from the glue. Products : Setting : Rapid Setting Mortars : ProLite® RS Premium Rapid Setting Large Format Tile Mortar. Precision demands the best. Whatever the application, CUSTOM® offers the broadest line of tile and stone setting materials in the industry to give the exact performance your job demands. Let the mixture slake or stand 5-10 minutes; stir again and use. Concrete or plaster must be fully cured and must accept water penetration. When setting moisture sensitive natural stone, cement or agglomerate tile use EBM-Lite™ Epoxy Bonding Mortar 100% Solids or CEG-Lite™ 100% Solids Commercial Epoxy Grout. with a properly applied sealer or a primer coat of RedGard, consisting of 1 part RedGard diluted with 4 parts clean, cool water. Submerged installations must cure for 14 days before filling with water. or [50-mm] Cube Specimens), ASTM C627 Standard Test Method for Evaluating Ceramic Floor Tile Installation Systems Using the Robinson-Type Floor Tester, Up to 2 points towards MR Credit 5, Regional Materials, Up to 2 points towards MR Credit 4, Recycled Content, Up to 1 point towards IEQ Credit 4.1, Low-Emitting Materials – Adhesives & Sealants, Vitreous, semi-vitreous or non-vitreous tile: ceramic, mosaic, quarry, cement body tile, Concrete, mortar beds, masonry, Portland cement plaster, Liquid applied waterproofing membranes such as, Crack prevention sheet membranes such as Crack Buster® Pro, Exterior Grade Plywood Substrates meeting deflection requirements (interior residential and light commercial dry areas), Fully bonded sheet vinyl flooring (scarified), Cutback adhesive (see preparation instructions). Roughen the surface by sanding or scarifying; rinse and allow to dry. Expansion joints and cold joints, as described in ANSI A108.01, should never be bridged with setting material. Obtain the applicable LIMITED PRODUCT WARRANTY at www.custombuildingproducts.com/product-warranty or send a written request to Custom Building Products, Inc., Five Concourse Parkway, Atlanta, GA 30328, USA. For more sizes, use the material calculator at CustomBuildingProducts.com or contact CUSTOM Technical Services at 800-282-8786. Tile grout with dependable performance and color. High Bond Strength 2.1 MPa Immediately holds wall tiles in place with ‘absolutely no slip!’ Quality begins from the ground up. When This product contains Portland cement and free silica. Do not sand or grind adhesive residue, as harmful dust may result. Capable of thin-set or medium bed application up to 3/4" (19 mm) thick on horizontal surfaces after beat-in. Do not sand flooring that contains asbestos. Use clean mixing-tools and containers. Professional Solutions for Professional Results Manufactured under the authority of Custom Building Products, Inc. © 2017 Quikrete International, Inc. Ideal for mixing concrete, just add cement powder. Modified dry-set mortar, which is a proprietary blend of Portland cement, inorganic aggregates, copolymers and chemicals. Careers | Drying time depends on site conditions, but is normally less than 1 hour. of traditional mortar, Allows grouting in as little as 3 hours and foot traffic in 4 hours, Non-slump medium bed for heavy tile and stone installations for floors and walls, Exceeds ANSI A118.15, A118.4 and A118.11 standards without the need for additives, ASTM C109 Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. Back buttering may be necessary. The primer can be brushed, rolled or sprayed to achieve an even coat. Installation must conform to ANSI A108.5. At a ratio of 1 part cement to 4 parts perlite, you achieve a "k" value of 0.83 and compressive strength of 350 to 500 pounds per inch. Resilient Floor Covering Institute (RFCI) Recommended Work Practices for Removal of Resilient Floor CoveringsTile Council of North America (TCNA) TCNA Handbook for Ceramic Tile Installation, TCNA Method EJ171International Organization for Standardization (ISO) 13007-2 for Thin Set Mortar. Concrete slabs should have a coarse finish to enhance the bond. Mix 5.75 - 6 qts (5.4 - 5.7 L) clean water per 30 lb (13.6 kg) bag of mortar. Mix in a clean bucket at low speed to obtain a lump free solution. Terms | American National Standards Institute (ANSI) ANSI A108.5, A118.4TE, A118.15TE and A118.11 American National Standards for the Installation of Ceramic Tile. DIY'ers look to us for help. Call Custom® Technical Services when installing natural stone over plywood subfloor. Adjust the tile promptly and beat it in with a beating block and rubber mallet. When setting dimensional stone larger than 12" x 12" (30 x 30 cm), contact Custom's® Technical Services for recommendations regarding subfloor deflection requirements. Press the tile firmly into place in a perpendicular motion across ridges, moving back and forth. Sitemap. All Lightweight cement or Gypsum surfaces should be primed. Properly installed tile will last for more than 60 years. Do not breathe dust; wear a NIOSH approved respirator. Movement joints are required for perimeters and other changes of plane in all installations. Custom Prolite® Tile and Stone mortar was mixed water per manufacturer’s instructions (mix ratio 38:100 by weight) and was troweled over the concrete subfloor with a 1/2" x 1/2" Euro notched trowel. Thin Set Mortar should not be used to fill low spots in the flooring. Maximum allowable deflection: L/360 tile L/720 stone. Back buttering may be necessary. Expansion joints should never be bridged with setting material. Mortar thickness should be less than 3/4" when beat in. Concrete slabs should have a coarse finish to enhance the bond. The foundation of precise tile and stone setting. All Rights Reserved. When properly mixed, troweled ridges will stand without slump. Mix 5.75 - 6 qts (5.4 - 5.7 L) clean water per 30 lb (13.6 kg) bag of mortar. Remove all grease, oil, dirt, curing compounds, sealers, adhesives or any other contaminant that would prevent a good bond. At this point, RedGard can be applied to the primed lightweight or gypsum based surface. Mix 5.75 - 6 qts (5.4 - 5.7 L) clean water per 30 lb (13.6 kg) bag of mortar. Exceeds ANSI A118.4TE, A118.15TE and A118.11 without the need for additives. Non-slump performance for floor installations. Mix by hand or use a low 150-200 RPM speed 1/2" (13 mm) drill to achieve a smooth, paste-like consistency. If you mix too little, your job will be compromised. Installation must conform to ANSI A108.5. Chemical Name CAS Number Weight %. Custom® Building Products is committed to environmental responsibility in both products produced and in manufacturing practices. Properly installed product requires no special maintenance. Plywood floors, including those under resilient flooring, must be structurally sound and must meet all ANSI A108.01 Part 3.4 requirements. CustomTech – the industry’s leading collection of technologically-superior, easy-to-use, professional grade subfloor preparation products designed for all types of floor coverings. Movement joints are required for perimeters and other changes of plane in all installations. When setting moisture sensitive natural stone, cement or agglomerate tile use EBM-Lite™ Epoxy Bonding Mortar 100% Solids or CEG-Lite™ 100% Solids Commercial Epoxy Grout. Surfaces must be structurally sound. To determine desirable results, do a test bond area before starting. Let the mixture slake or stand 5-10 minutes; stir again and use. Never use adhesive removers or solvents, as they soften the adhesive and may cause it to penetrate into the concrete. 1K Club Member Join Date Nov 2008 Location Sydney Posts 1,108. Offering the largest selection of Sealers, Cleaners, Problem Solvers, Grout Colorant and Stone Restoration products, we provide professionals with the right tools and solutions; making us the #1 Contractor Preferred Manufacturer of Sealers and Cleaners. Press the tile firmly into place in a perpendicular motion across ridges, moving back and forth. Surfaces shall be free of all grease, oil, dirt, dust, curing compounds, waxes, sealers, efflorescence, or any other foreign matter. or [50-mm] Cube Specimens), ASTM C627 Standard Test Method for Evaluating Ceramic Floor Tile Installation Systems Using the Robinson-Type Floor Tester, Up to 2 points towards MR Credit 5, Regional Materials, Up to 2 points towards MR Credit 4, Recycled Content, Up to 1 point towards IEQ Credit 4.1, Low-Emitting Materials – Adhesives & Sealants, Vitreous, semi-vitreous or non-vitreous tile: ceramic, quarry, cement body tile, pavers, Concrete, mortar beds, masonry, Portland cement plaster, Liquid-applied and waterproofing membranes such as, Exterior Grade Plywood (interior residential and light commercial dry areas), Fully-bonded sheet vinyl flooring (scarified), Cutback adhesive (see preparation instructions). Manufactured under the authority of Custom Building Products, Inc. © 2017 Quikrete International, Inc. Purchase by the bag or See TCNA F150-13 tile installations, TCNA F141-13 and F250-13 for stone. Note that mortar coverage does not include backbuttering tiles. Curing time is affected by ambient and surface temperatures and humidity. The mix ratio was not the contention, it was the overall amount. We give it. Stains can RUIN Stone & Tile.Protect Yours Now! Concrete must be cured 28 days and accept water penetration. Mixing Ratios Mix 5.75 - 6 qts (5.4 - 5.7 L) clean water per 30 lb (13.6 kg) bag of mortar. Properly installed tile may last for more than 60 years. Protect your surface against both oil-based and water-based stains with the right sealer. Extremely porous surfaces may require 2 coats. SQUARE FOOT COVERAGE PER 30 LB BAG (SQUARE METER PER 13.6 KG). Stains on stone, tile or grout happen easily - and can leave permanent stains. When properly mixed, troweled ridges will stand without slump. Formulated with post-consumer recycled material, it contributes to LEED® certification. ProLite® contains up to 22% recycled content by weight and 48% recycled content by volume. SQUARE FOOT COVERAGE PER 30 LB BAG (SQUARE METER PER 13.6 KG). It is also used to set porcelain tile and natural stone tile. Allow 24 hours before grouting and light traffic. To find out how much water to use, read the instructions on the bag. Mixing Procedures Mix by hand or use a low 150 – 200 rpm speed 1/2" (13 mm) drill to achieve a smooth, paste-like consistency. Expansion joints must be installed in accordance with local building codes and ANSI/TCNA guidelines. Formulated with recycled material contributes to LEED certification. Thinset mortar is commonly used for setting ceramic tile. Stir occasionally, but do not add more water. Then use a stabbing motion across the top to work the moisture through the mixture until it is consistent. This product contains Portland cement and free silica. Please contact our sales team on 3219 7456 for a quote Benefits Of 10mm Concrete Blend: Mixed in the correct ratios ready to add cement. Call Custom® Technical Services when installing natural stone over plywood subfloor. If eye contact occurs, flush with water for 15 minutes and consult a physician. Lightweight or gypsum based underlayments must obtain a minimum 2000 psi (13.8 MPa) compressive strength. Periodically pull up a tile and check the back to ensure proper adhesive coverage. Refer to the RFCI Pamphlet, "Recommended Work Practices for Removal of Resilient Floor Coverings", for further information. American National Standards Institute (ANSI) - ANSI A108.5, A118.4, A118.5 and A118.11 of the American National Standards for the Installation of Ceramic TileISO 13007-2, Resilient Floor Covering Institute — (RFCI) Recommended Work Practices for Removal of Resilient Floor CoveringsTile Council of North America (TCNA) — TCNA Handbook for Ceramic Tile Installation, TCNA Method EJ171. Rinse and allow to dry. There are a variety of mortar mixes that the mason contractor can mix up, depending on the type of material that is being installed: Type M (2500 psi) Type S (1800 psi) Type N (750 psi) The different types are achieved by varying the ratio of Portland Cement, Lime and Sand. Tile grout with dependable performance and color. As an alternative to an additional layer of plywood, WonderBoard Lite backerboard may be installed over plywood subfloors for ceramic tile installations. As necessary, use plywood or other load distributing protection when moving heavy equipment across tiled assembly. Mix 6 qts (5.67 L) clean water per 50 lb (22.68 kg) bag of mortar. Don’t be afraid to add more water or mortar to get it right. Mixing Ratios. Roughen the surface by sanding or abrading, then rinse and allow to dry. Plywood flooring including those under resilient flooring must be structurally soundand meet all ANSI and deflection requirements. Mixing Procedures Mix by hand or use a low 150-200 RPM speed 1/2" (13 mm) drill to achieve a smooth, paste-like consistency. After a quick test, I can tell you that the ratio is 8 parts thinset mortar by volume to three parts water. Concrete must be free of efflorescence and not subject to hydrostatic pressure. Before exposure to heavy or vehicular traffic, assure assembly is rated “Heavy or Extra Heavy” per TCNA Service Requirements. Most bags of thinset mortar come with instructions for mixing the entire bag. Concrete slabs should have a coarse finish to enhance the bond. Different size tile requires that you use a specific size trowel. For more sizes, use the material calculator at CustomBuildingProducts.com or contact CUSTOM Technical Services at 800-282-8786. How to Tile a Shower Wall (9 Quick Tips) - Duration: 9:04. Sitemap. bag of ProLite covers the same area as a 50 lb. Privacy | Ambient temperature should be maintained above 50° F (10° C) or below 100° F (38° C) for 72 hours to achieve proper bond. How to mix thinset mortar the proper way, - Duration: 12:22. Refer to TCNA EJ171. Contaminants should be mechanically removed before installation. Let the mixture slake or stand 5-10 minutes; stir … Mixing Mixing Ratio: 2 1/2 parts powder to 1 part water 1. When backbuttering, consider the tile underside pattern and depth to estimate thickness and usage to add to your estimate. METHODS Mixing Mix 5.5 qt (5.21 L) clean water to 30 lb (13.6 kg) bag of mortar. Mortar mix is a critically important building component that must be combined thoroughly. Concrete slabs should have a coarse finish to enhance the bond. Expansion joints should never be bridged with setting material. Exceeds ANSI A118.15, A118.4 and A118.11 without the need for additives. Test by sprinkling water on various areas of the substrate. When setting dimensional stone larger than 12" x 12" (30 x 30 cm), contact Custom's® Technical Services for recommendations regarding subfloor deflection requirements. Do not bond directly to hardwood, Luan plywood, particle board, parquet, cushion or sponge-back vinyl flooring, metal, fiberglass, plastic or OSB panels. Apply the primer coat to the floor at a rate of 300 ft2/gal (7.5 M2/L). A 30 lb. The consistency is very important. Refer to TCNA EJ171. With some tile, back-buttering is advisable. Custom® Building Products is committed to environmental responsibility in both products produced and in manufacturing practices. Mailing Address Custom Building Products 7711 Center Ave. Ste 500 Huntington Beach, CA 92647, © 2020 Custom Building Products. The perpendicular motion flattens ridges and closes valleys, allowing maximum coverage. The primer can be brushed, rolled or sprayed to achieve an even coat. bag of traditional mortar. Refer to the RFCI Pamphlet, "Recommended Work Practices for Removal of Resilient Floor Coverings", for further information. Excellent for setting large format tile (LFT), heavy tile or stone, ProLite® will not sag or slip on walls and offers non-slump performance for floor installations. Protect your surface against both oil-based and water-based stains with the right sealer. Surfaces to be tiled must be structurally sound and subject to deflection not to exceed the current ANSI Standards. If water penetrates, then a good bond can be achieved; if water beads, surface contaminants are present, and loss of adhesion may occur. Coverage may vary based on installation practices and jobsite conditions. Refer to the individual product data sheet or packaging directions for application instructions. Mortar is the bonding material between bricks, concrete block, stone, and many other masonry materials.It is made from Portland cement, lime, sand, and water in varying ratios. If you follow these steps you will have perfect thin set every single time. Look for tile grout with rock-solid durability, consistency and the largest color palette with Custom. Modified dry mortar, which is a proprietary blend of Portland cement, inorganic aggregates, copolymers and chemicals. For existing well-bonded ceramic tile, mechanically abrade the surface. The foundation of precise tile and stone setting. Use of this product can contribute towards LEED® v3 certification: USE CHEMICAL-RESISTANT GLOVES, such as nitrile, when handling product. The perpendicular motion flattens ridges and closes valleys, allowing maximum coverage. It might seem like a simple thing, how to mix thinset Mortar, just add some water to some powder and stir it a bit, wrong. Stir occasionally, but do not add more water. Roughen the surface by sanding or scarifying; rinse and allow to dry. Privacy | Step 5. The underlayment must be sufficiently dry andproperly cured to the manufacturer’s specifications for permanent, non-moisture permeable coverings. Perlite is a natural filtration system, allowing excess water to easily drain away while retaining a little moisture and catching nutrients that plants need to grow. Do not use to install resin-backed stone use EBM-Lite™ Epoxy Bonding Mortar 100% Solids, CEG-Lite™ 100% Solids Commercial Epoxy Grout or contact Custom's® Technical Services for recommendations. (13.6 kg) bag covers the same area as a 50 lb. For existing well bonded ceramic tile, mechanically abrade the surface. Concrete must be cured 28 days and accept water penetration. Avoid eye contact and prolonged contact with skin. Mixing Mix 5.5 - 6 qts (5.2 - 5.6 L) clean water per 50 lb (22.68 kg) bag of mortar. You know you have it right if the mortar on your trowel doesn’t drip off but can be shaken off. Concrete must be free of efflorescence and not subject to hydrostatic pressure. The Plane Collection tile was back-buttered with a scratch Smooth concrete surfaces, existing glazed tile, terrazzo, or polished stone should be scarified. CUSTOM will repair and/or replace, at its discretion, the affected area of the system. For questions about proper subfloor installation, call Technical Services. Type M. The last of the four most common mortar types is type M. This type is considered the strongest on its own, with a compressive strength of … Use the following as a guideline. Concrete must be free of efflorescence and not subject to hydrostatic pressure. Non-slump - for use as a thin or medium bed mortar up to 3/4 in. Expansion joints, perimeter joints and cold joints, as described in ANSI A108.01, should never be bridged with setting material. This technologically advanced mortar offers high-performance and flexibility designed to meet the rigors of setting large format tile and stone for fast track commercial or residential installations. We are professionals. Sal DiBlasi 69,037 views. Recommended minimum coverage (80% for dry areas and 95% for wet areas and exteriors). covers the same area as 50 lbs. In this article I will show you how easy it is to mix thin set when following just a few simple steps. of traditional mortar, Suited for thin-set and medium bed mortar applications, Non-slip, non-slump for heavy floor and wall tile and stone installation up to 3/4" (19 mm) thick, Exceeds ANSI A118.4TE, A118.15TE and A118.11 standards without the need for additives, 40% lighter than traditional mortars. The amount of thinset you need is calculated by the square footage of the floor or wall, the size of the tile, and the size of notched trowel you use to spread it. Refer to TCNA EJ171, F125 and F125A. Use a properly-sized notch trowel to ensure proper coverage under tiles. Ambient temperature should be maintained above 50° F (10° C) or below 100° F (38° C) for 72 hours to achieve proper bond. Surfaces must be structurally sound. Mailing Address Custom Building Products 7711 Center Ave. Ste 500 Huntington Beach, CA 92647, © 2020 Custom Building Products. Smooth concrete slabs must be mechanically abraded to achieve proper bond. Adhesive layers must be removed, as they reduce mortar bond strength to cement surfaces. Home Repair Tutor 554,504 views. Plywood flooring including those under resilient flooring must be structurally sound and meet all ANSI and deflection requirements. Smooth concrete surfaces, existing glazed tile, terrazzo, or polished stone should be scarified. Custom Building Products offers you one source for the needs of virtually any job. If you mix too much, the job is done and you have a little waste. SuperiorBilt® Tools are professionally preferred for tile, stone and floor covering installations. Let the mixture slake or stand 5-10 minutes; stir again and use. Type N mortar This uses a 1 / 1 / 6 mix and results in a mortar with a 750 psi compressive strength. Formulated with recycled material and contributes to LEED® certification. CustomTech – the industry’s leading collection of technologically-superior, easy-to-use, professional grade subfloor preparation products designed for all types of floor coverings. Let the mixture slake or stand 3 minutes; stir again and use. Mixing Procedures Mix by hand or use a low 150-200 RPM speed 1/2" (13 mm) drill to achieve a smooth, paste-like consistency. Tip the dry pre-mix mortar into the wheelbarrow. Do not sand flooring materials containing asbestos. Lightweight or gypsum-based underlayments must obtain a minimum 2000 psi (13.8 MPa) compressive strength. All Rights Reserved. Offering the largest selection of Sealers, Cleaners, Problem Solvers, Grout Colorant and Stone Restoration products, we provide professionals with the right tools and solutions; making us the #1 Contractor Preferred Manufacturer of Sealers and Cleaners. Concrete or plaster must be fully cured and must accept water penetration. Capable of thin-set or medium bed application up to 3/4" (19 mm) thick on horizontal surfaces after beat-in. Sheet vinyl must be well bonded and stripped of old finish. Smooth concrete slabs must be mechanically abraded to achieve proper bond. 10mm Concrete Blend is available in 1 tonne bulk bags. Let the mixture slake or stand 5-10 minutes; stir again and use. Recommended minimum coverage (80% for dry areas and 95% for wet areas and exteriors). Privacy, Contact | Using one part water to four parts thinset powder should work for most quantities. At this point, RedGard can be applied to the primed lightweight or gypsum based surface. One part formula with no need for a separate liquid additive to improve bond strength, flexibility or performance. Careers | See TCNA F150-13 tile installations, TCNA F141-13 and F250-13 for stone. Contaminants should be mechanically removed before installation. Perlite concrete mixed at a ratio of 1 part cement to 6 parts perlite has an insulation value, or "k" value, of 0.64 and a compressive strength of 125 to 200 pounds per square inch. See Safety Data Sheet for more information. Use the following as a guideline. Randy1953, welcome to the forums! For questions about proper subfloor installation requirements, call Custom® Technical Services. Do not bond directly to hardwood, Luan plywood, particle board, parquet, cushion or sponge-back vinyl flooring, metal, fiberglass, plastic or OSB panels. Mix by hand or use a low 150-200 RPM speed 1/2" (13 mm) drill to achieve a smooth, paste-like consistency. WonderBoard Lite backerboard may be installed over structurally sound plywood subfloors for ceramic tile installations. Versabond-LFT Fortified Medium Bed Mortar is a professional grade polymer-modified medium bed mortar for use with large format porcelain, ceramic and natural stone tile. Roughen the surface by sanding or abrading, then rinse and allow to dry. Expansion joints must be installed in accordance with local building codes and ANSI/TCNA guidelines. Surfaces shall be free of all grease, oil, dirt, dust, curing compounds, waxes, sealers, efflorescence, or any other foreign matter. Do not sand or grind adhesive residue, as harmful dust may result. View All CustomTech Flooring Prep Products, Waterproofing and Crack Prevention Membrane, www.custombuildingproducts.com/product-warranty, CEG-Lite™ 100% Solids Commercial Epoxy Grout, ProLite® RS Premium Rapid Setting Large Format Tile Mortar, Longest side of tile less than 8" use 1/4" x 1/4" x 1/4" (6 x 6 x 6 mm) Square-Notch, Longest side of tile 8" to 15" use 1/4" x 3/8" x 1/4" (6 x 9.5 x 6 mm) Square-Notch, Longest side of tile more than 15"+ use 1/2" x 1/2" x 1/2" (13 x 13 x 13 mm) Square-Notch, Longest side of tile more than 15"+ use 3/4" × 9/16" × 3/8" (19 × 14 × 9.5 mm) U-Notch, Non-slump - For use as a thin or medium bed mortar up to 3/4", Sag and slip resistant - immediately holds wall tiles in place, Lightweight - 30 lbs. Chart for estimating purposes. Allow 3 hours before grouting, 4 hours before light traffic, and 3 days before heavy or vehicular traffic. Meets ANSI A138.1 for Sustainable Tile Installation Products. Running out of mortar mix after you've started your project can affect both your schedule and the quality of your work, while stocking up on too much mortar is a waste of money. But if your trying to match grout use a sanded grout .With either method use grout booster in the mix. If you have a small amount of tile to set, use 4 ounces or 1/2 cup of water to 1 pound of dry thinset powder. Mixing Ratios. Wash thoroughly after handling. As mentioned earlier, perlite offers a lot of benefits to your garden. View All CustomTech Flooring Prep Products, www.custombuildingproducts.com/product-warranty, Longest side of tile less than 8" use1/4" x 1/4" x 1/4" (6 x 6 x 6 mm) Square-Notch, Longest side of tile 8" to 15" use 1/4" x 3/8" x 1/4" (6 x 9.5 x 6 mm) Square-Notch, Longest side of tile more than 15"+ 1/2" x 1/2" x 1/2" (13 x 13 x 13 mm) Square-Notch, Longest side of tile more than 15"+ 3/4" × 9/16" × 3/8" (19 × 14 × 9.5 mm) U-Notch, Fast curing - Grout in 3 hours, open for traffic in 4 hours, Non-slump for floors, sag and slip resistant for walls, Lightweight - 30 lbs. The thin-set was combed with the notched side to form parallel ridges. With the notch side of the trowel held at a 45° angle, apply additional mortar to the surface, combing in one direction. For questions about proper subfloor installation, call Technical Services. Whatever the application, CUSTOM® offers the broadest line of tile and stone setting materials in the industry to give the exact performance your job demands. source. Let the mixture slake or stand 5-10 minutes; stir again and use. Drying time depends on site conditions, but is normally less than 1 hour. Chart for estimating purposes. 12:22. When sanding, an approved respirator should be used. As necessary, use plywood or other load distributing protection when moving heavy equipment across tiled assembly. Contact Custom's® Technical Services for the proper treatment of control or saw cut joints. Mixing Procedures Mix by hand or use a low 150-200 RPM speed 1/2" (13 mm) drill to achieve a smooth, paste-like consistency. make sure u pack it in solid and wipe clean after 15 mins. When ProLite® Rapid Setting Tile & Stone Mortar is used as a part of a qualifying full installation system of CUSTOM products, the installation can qualify for up to a 15 year system warranty. Mix in a clean bucket at low speed to obtain a lump free solution. Look for tile grout with rock-solid durability, consistency and the largest color palette with Custom. Use extreme caution; adhesives may contain asbestos fibers. All lightweight cement or gypsum surfaces should be primed. (22.68 kg) bag of traditional mortar. Custom Building Products offers you one source for the needs of virtually any job. Coverage may vary based on installation practices and jobsite conditions. Use a properly-sized notch trowel to ensure proper coverage under tiles. Adhesive layers must be removed, as they reduce mortar bond strength to cement surfaces. 2nd May 2012, 06:22 PM #4. cherub65. Adhesive residue must be wet scraped to the finished surface of the concrete, leaving only the transparent staining from the glue. Wash thoroughly after handling. I won't comment on your rhetoric at this point. Quality begins from the ground up. 10mm Concrete Blend A mixture of 10mm gravel and sand. Glossy or painted surfaces must be sanded, or abraded, and stripped of all contaminants. Thin-Set Mortar should not be used to fill low spots in the flooring. Stir occasionally, but do not add more water. Our grouts are easy to work with yet deliver hard, dense joints. Mixing Ratios Mix 5.5 - 6 qts (5.2 - 5.6 L) clean water per 50 lb (22.68 kg) bag of mortar. Products : Setting : Large Format Tile Mortars : ProLite® Premium Large Format Tile Mortar. With the notch side of the trowel held at a 45° angle, apply additional mortar to the surface, combing in one direction. In a clean mixing container, measure and pour 4.75 L (5 quarts / 1.25 US gal) of cool clean water and gradually add 11.34 kg (25 lb) of PRO SUPERLITE MORTAR powder mix, while mixing slowly. Mortar plays a critical role in masonry construction, serving as a form of adhesive to join brick and block. Rinse and allow to dry. If the material has skinned over (not sticky to the touch), recomb with the notch trowel; if too dry, remove and replace the dry material with fresh material. For more information, find details and limitations to this warranty at custombuildingproducts.com. Mixing Ratios Mix 5.5 qts (5.21 L) clean water per 30 lb (13.6 kg) bag of mortar. The underlayment must be sufficiently dry and properly cured to the manufacturer’s specifications for permanent, non-moisture permeable coverings. Perlite as a part of a 3 part DIY potting mix. Avoid eye contact or prolonged contact with skin. Professional Solutions for Professional Results with a properly applied sealer or a primer coat of RedGard, consisting of 1 part RedGard diluted with 4 parts clean, cool water. Movement joints are required for perimeters and other changes of plane in all installations. If eye contact occurs, flush with water for 15 minutes and consult a physician. A 30 lb. covers the same area as 50 lbs. When sanding, an approved respirator should be used. Movement joints are required for perimeters and other changes of plane in all installations. Mix your thinset mortar and water until it has the consistency of a thick peanut butter. Excellent open time and adjustability. Do not sand flooring that contains asbestos. Type N is the normal, general purpose mortar mix and can be used in above grade work in both exterior and interior load-bearing installations. Mix by hand or use a low 150 – 200 rpm speed 1/2" (13 mm) drill to achieve a smooth, paste-like consistency. Portland cement 65997-15-1 40 – 70%* Soda Lime Glass 65997-17-3 15 – 40%* Calcium Carbonate 1317-65-3 10 – 30%* Crystalline silica, quartz 14808-60-7 0.1 – 1.0%* *Means that the component will fall into one the ranges specified due to batch-to-batch variability. Stir occasionally, but do not add more water. Obtain the applicable LIMITED PRODUCT WARRANTY at www.custombuildingproducts.com/product-warranty or send a written request to Custom Building Products, Inc., Five Concourse Parkway, Atlanta, GA 30328, USA. A 30 lb. Properly installed product requires no special maintenance. When setting glass tile larger than 6" x 6" (15 x 15 cm), contact Custom's® Technical Services for recommendations. Clean with water before the material dries. Let the mixture slake or stand 5 – 10 minutes; stir again and use. When ProLite® Tile & Stone Mortar is used as a part of a qualifying full installation system of CUSTOM products, the installation can qualify for up to a 15 year system warranty. Mix 5.75 - 6 qts (5.4 - 5.7 L) clean water per 30 lb (13.6 kg) bag of mortar. CUSTOM will repair and/or replace, at its discretion, the affected area of the system. With some tile, back-buttering is advisable. To get 1 cuyd of N mortar, you need 27 cubic feet of the components in a 1 to 1 to 6 Before exposure to heavy or vehicular traffic, assure assembly is rated “Heavy or Extra Heavy” per TCNA Service Requirements. Available in a 13.5kg bag ProLite will cover the same area as a 20kg bag of traditional tile adhesive. Resilient flooring or plastic laminates must be well-bonded, as well as clean and free of all contaminates. Privacy, Contact | Then pour water over the top. Note that mortar coverage does not include backbuttering tiles. Never use adhesive removers or solvents, as they soften the adhesive and may cause it to penetrate into the concrete. Contact Custom's® Technical Services for the proper treatment of control or saw cut joints. Refer to TCNA EJ171, F125 and F125A. Stir occasionally, but do not add more water. Adjust the tile promptly and beat it in with a beating block and rubber mallet. Mixing Procedures Mix by hand or use a low 150-200 RPM speed 1/2" (13 mm) drill to achieve a smooth, paste-like consistency. Glossy or painted surfaces must be sanded, or abraded, and stripped of all contaminants. Installation must comply with the requirements of all applicable local, state and federal code jurisdictions. Do not use to install resin-backed stone use EBM-Lite™ Epoxy Bonding Mortar 100% Solids, CEG-Lite™ 100% Solids Commercial Epoxy Grout or contact Custom's® Technical Services for recommendations. If you don't, then you could have problems. Curing time is affected by ambient and surface temperatures and humidity. Stains can RUIN Stone & Tile.Protect Yours Now! Extremely porous surfaces may require 2 coats. SuperiorBilt® Tools are professionally preferred for tile, stone and floor covering installations. Also available in a rapid setting formula (See ProLite® RS). This video show how to mix modified thin set mortar properly in order to get the right consistency according to the manufacture instructions. A 30 lb (13.6 kg) bag covers the same area as a 50 lb (22.68 kg) bag of traditional mortar, ASTM C109 Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. Exceeds ANSI A118.4TE, A118.15TE and A118.11 without the need for additives. 3. A lightweight, medium bed, rapid-setting mortar. Stir occasionally, but do not add more water. For clear or translucent glass, CUSTOM recommends Glass Tile Premium Thin-Set Mortar. Refer to TCNA F144-13 tile installations, TCNA F250-13 stone installations. Stir occasionally, but do not add more water. 2. Concrete must be free of efflorescence and not subject to hydrostatic pressure. Sheet vinyl must be well bonded and stripped of old finish. They must be brought through the tile work and filled with an appropriate elastomeric sealant, such as Custom's® 100% Silicone.